Shenzhen Hongswell Technology Co. , Ltd.

Home Products PVC insulated power cable IEC 60502-1 0.6/1 kV PVC Insulated Power Cable Copper conductor class 2 PVC Insulated and sheathed From 1 to 5 core

Products

IEC 60502-1 0.6/1 kV PVC Insulated Power Cable Copper conductor class 2 PVC Insulated and sheathed From 1 to 5 core
IEC 60502-1 0.6/1 kV PVC Insulated Power Cable Copper conductor class 2 PVC Insulated and sheathed From 1 to 5 core IEC 60502-1 0.6/1 kV PVC Insulated Power Cable Copper conductor class 2 PVC Insulated and sheathed From 1 to 5 core

IEC 60502-1 0.6/1 kV PVC Insulated Power Cable Copper conductor class 2 PVC Insulated and sheathed From 1 to 5 core

Product ID : 004
Product Attributes :
Place of Origin:Shenzhen, Mainland China
Brand Name:Hongswell Technology
Certification:CE, CB
Model Number:NYY

Payment & Shipping Terms:

Minimum Order Quantity:500 m
Price:On Request
Packaging Details:Steel Wooden Drum
Delivery Time:15 working days after payments
Payment Terms:L/C, T/T


Product Description
Nominal Voltage:0.6/1 KVCore Insulation:PVC
No. Of Conductor:From 1 To 5Outer Sheath:PVC
Conductor Material:Bare Copper Class 2Manufacturer:Shenzhen Hongswell


 

PVC Insulated Power Cable

 

Copper Conductor, PVC Insulated & Sheathed

 

 

APPLICATIONS:

 

Power cables for energy supply are installed in open air, in underground, indoors, in cable ducts, power stations, residental connections and street lighting as well as in subscriber networks, where mechanical damages are not be expected.

 

STANDARDS

 

International: IEC 60502-1
National:GB/ T 12706.1-2008

 

CONSTRUCTION:

1. CONDUCTOR
–  Bare copper conductor, Class 2 to IEC 60228

 

2. INSULATION
–  PVC Compound


3. FILLER

–   PP filler

 

4. INNER SHEATH(in case of armoured cable)

–  PVC Compound

 

5. ARMOUR

–  Two steel tape

 

6. OUTER SHEATH :
–  PVC Compound

 

Sheath colour :
–  Black

 

*Note: when required for a particular application, other colors are available.

 

  Electrical Characteristics

 

Rated Voltage Uo/U0.6/1 kV
Maximum operating voltage1.2 kV
Frequence50 Hz
Test voltage :3500 V
 

  Usage Characteristics

 

Permissible operating temperature at conductor70°C
short circuit temperature ( duration max. 5 s)160 °C
Minimum installation temperatureshould not be lower than 0°C
Max. conductor permissible tensile stress50 N/mm²
Minimum bending radius12 x cable Ø

 

 

  SINGLE CORE CABLE (UNARMOURED) Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²mmmmmmkg / kmAAΩ/km
1×1.50.81.46.161242912.1
1×2.50.81.46.57431387.41
1×4.01.01.47.410041494.61
1×6.01.01.47.912452613.08
1×101.01.49.218372831.83
1×161.01.410.3251951051.15
1×251.21.412.03671201350.73
1×351.21.413.14751501600.52
1×501.41.414.96181801950.39
1×701.41.416.98402302400.27
1×951.61.519.311342802850.19
1×1201.61.521.113843253250.15
1×1501.81.623.116833753650.12
1×1852.01.725.620844304150.10
1×2402.21.828.926965104800.08
1×3002.41.931.733555855450.06
1×4002.62.033.042466906250.05
1×5002.82.137.250928007100.04
1×6302.82.240.563629208100.03

 

  2 CORE CABLE (UNARMOURED) Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²mmmmmmkg / kmAAΩ/km
2×1.50.81.810.5129192512.1
2×2.50.81.811.315826347.41
2×4.01.01.813.022135444.61
2×6.01.01.814.027444563.08
2×101.01.816.737860761.83
2×161.01.818.8519801001.15
2×251.21.822.67581071290.73
2×351.21.819.29781311570.52
2×501.41.822.012171521870.39
2×701.41.924.316131942330.27
2×951.62.027.021572382780.19
2×1201.62.130.026582753180.15
2×1501.82.233.032963183570.12
2×1852.02.436.840273664040.10

 

 

  2 CORE CABLE (ARMOURED) Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²mmmmmmkg / kmAAΩ/km
2×41.01.816.338834444.61
2×61.01.817.345443533.08
2×101.01.820.058958701.83
2×161.01.822.074877921.15
2×251.21.825.510291041220.73
2×351.21.827.812761291490.52
2×501.41.826.514871461710.39
2×701.41.930.321781882140.27
2×951.62.134.228002402670.19
2×1201.62.236.533652743060.15
2×1501.82.440.040593163460.12
2×1852.02.543.849843683940.10

 

  3 CORE CABLE (UNARMOURED) Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²mmmmmmkg / kmAAΩ/km
3×1.50.81.811154172212.1
3×2.50.81.811.919422297.41
3×4.01.01.813.827429384.61
3×6.01.01.814.934837473.08
3×101.01.817.652952651.83
3×161.01.819.974068851.15
3×251.21.823.71058911100.73
3×351.21.826.113821121340.52
3×501.41.826.417601331590.39
3×701.42.029.823641711990.27
3×951.62.133.831582092370.19
3×1201.62.236.739212422710.15
3×1501.82.340.248682823050.12
3×1852.02.545.659523293460.10
3×2402.22.751.777133924000.08
3×3002.42.956.1100044504620.06

 

  3 CORE CABLE (ARMOURED) Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²mmmmmmkg / kmAAΩ/km
3×41.01.817.045029364.61
3×61.01.818.153837453.08
3×101.01.820.874550601.83
3×161.01.823.198366791.15
3×251.21.826.91344901050.73
3×351.21.829.317021111270.52
3×501.41.931.223441291480.39
3×701.42.034.430171651850.27
3×951.62.238.639132062210.19
3×1201.62.341.747412422610.15
3×1501.82.545.557902812960.12
3×1852.02.651.070133283370.10
3×2402.22.857.389303863890.08
3×3002.43.061.5113504454410.06

 

 

  4 CORE CABLE (UNARMOURED) Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²mmmmmmkg / kmAAΩ/km
4×41.01.814.933930384.61
4×61.01.816.143638483.08
4×101.01.819.366953661.83
4×161.01.821.895370861.15
4×251.21.826.01374941120.73
4×351.21.828.718101161350.52
4×501.41.929.523121391610.39
4×701.42.133.031051772020.27
4×951.62.238.141792172400.19
4×1201.62.441.151852542740.15
4×1501.82.545.864142943090.12
4×1852.02.750.579013373460.10
4×2402.22.955.7102494014030.08
4×3002.43.163.4133654704590.06

 

 

  4 CORE CABLE (ARMOURED) Physical and Electrical Characteristics:

 

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²mmmmmmkg / kmAAΩ/km
4×41.01.818.252930374.61
4×61.01.819.364138463.08
4×101.01.822.590553641.83
4×161.01.825.0121871831.15
4×251.21.829.21690941080.73
4×351.21.933.524791171320.52
4×501.42.034.329631401570.39
4×701.42.237.838311781960.27
4×951.62.443.150322192340.19
4×1201.62.546.361052552680.15
4×1501.82.651.074752943010.12
4×1852.02.856.290703333380.10
4×2402.23.061.3116643973930.08
4×3002.43.269.3150184644480.06

 

 

  4 CORE CABLE (UNARMOURED) Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²mmmmmmkg / kmAAΩ/km
5×41.01.816.240331394.61
5×61.01.817.552039493.08
5×101.01.821.081154671.83
5×161.01.823.8115672871.15
5×251.21.828.51778961110.73
5×351.21.931.323481181340.52
5×501.42.137.031291441590.39
5×701.42.242.043571861990.27
5×951.62.449.159532272350.19
5×1201.62.553.672982662690.15
5×1501.82.759.389473033020.12
5×1852.02.966.0111443523430.10
5×2402.23.174.6143274203980.08
5×3002.43.382.6178234834520.06

 

 

  4 CORE CABLE (ARMOURED) Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness
Inner Sheath thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²mmmmmmmmkg / kmAAΩ/km
5×41.00.91.819.460631384.61
5×61.00.91.820.773939473.08
5×101.00.91.824.2107255651.83
5×161.00.91.827.0145072851.15
5×251.20.91.831.92143961080.73
5×351.20.92.036.430981191310.52
5×501.41.22.241.639921451560.39
5×701.41.22.346.853561871950.27
5×951.61.22.554.171382252300.19
5×1201.61.42.658.886162632740.15
5×1501.81.42.864.7104292963010.12
5×1852.01.43.076.6128173353480.10
5×2402.21.43.280.8152263874090.08
5×3002.41.43.589.0200624394720.06
 
  3 +2 CORE PVC INSULATED & SHEATHED POWER CABLE(UNARMOURED)

 

No.cores x cross-sec.Insulation thicknessSheath thickness Nominal valueOuter Ø approx.weight approx.Current ratings in air 30℃Current ratings buried 20℃
PhaseNeutral
mm²mmmmmmmmkg / kmAA
3×4+2×2.51.00.81.815.33513038
3×6+2×4.01.01.01.817.04733848
3×10+2×6.01.01.01.819.76915266
3×16+2×101.01.01.822.010126986
3×25+2×161.21.01.826.8153693111
3×35+2×161.21.01.828.91872113134
3×50+2×251.41.21.934.22596141163
3×70+2×351.41.22.038.83524180203
3×95+2×501.61.42.244.44776221242
3×120+2×701.61.42.349.06124258276
3×150+2×701.81.42.453.77113298310
3×185+2×952.01.62.660.09046343349
3×240+2×1202.21.62.867.511558408406
3×300+2×1502.41.83.075.014389479462
  
3 +2 CORE STEEL TAPE ARMOURED POWER CABLE

 

No.cores x cross-sec.Insulation thicknessSheath thickness Nominal valueOuter Ø approx.weight approx.Current ratings in air 30℃Current ratings buried 20℃
PhaseNeutral
mm²mmmmmmmmkg / kmAA
3×4+2×2.51.00.81.818.54953037
3×6+2×4.01.01.01.820.26083846
3×10+2×6.01.01.01.822.98345264
3×16+2×101.01.01.826.011437084
3×25+2×161.21.01.830.2160793108
3×35+2×161.21.01.833.52060113130
3×50+2×251.41.21.938.82795142158
3×70+1×351.41.22.143.63581181199
3×95+2×501.61.42.349.44676222236
3×120+2×701.61.42.455.05751258269
3×150+2×701.81.42.559.16788297303
3×185+2×952.01.62.765.68371338340
3×240+2×1202.21.62.973.710523404396
3×300+2×1502.41.83.181.513572472450
 
*Dimensions and specifications may be changed without prior notice.
 

  Conductor Design

 
Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable

 

  Packaging & Delivery

 
Packaging details :

Delivery :

Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV CableDurable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable

Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable

Steel Wooden DrumsCable Drum In container shipped in 15 days after payment

 

  Cable Drum Data

 

CABLE DRUMSD1=Flange Diameter(mm)W=Useful Width (mm)D2=Barrel Diameter(mm)
Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable1000700500
1100700550
1200700600
1400750710
1600900900
180011201000
240011501300

 

 

  Delivery Port:

 

Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV CableDurable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV CableDurable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable
Port of Shenzhen Port of Hongkong Port of Guangzhou

 

  Manufacturing Process Of Low Voltage Power Cable ( Unarmored )

 
Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV CableDurable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable
1. copper rod2. wire drawing3. wire stranding
Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV CableDurable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV CableDurable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable
4.Inner sheath5. Assembling6.outer covering Process
Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV CableDurable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable0038038016183205_b_副本.jpg0038038016183205_b_副本.jpg
7. Sheath Marking8. Packing9. cable delivering

 

  Our production in numbers

 

Did you know

● Cable production started 1983
35 years of cable manufacturing experience

● Sales in 2016 about 500 million USD

100,000 m2 Production area
350 Will-trained employees
● Exported more than 22 countries
2 Manufacturing plant
1 R&D Center

200 Sets Of Testing Equipment

100 Testing Items
8 workshop
40 wire drawing machines
10 bunching machines
28 Extruder system
42 stranding machines
10 Braiding machines

 

  Some great shots of our manufactering plant

 
工厂.jpgDurable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV CableDurable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable
Mannufacturing plantR&D BuildingBird's eye view of the plant
Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable工厂2.jpg工厂5_副本.jpg
MV Power Cable WorkshopCable Reels Waiting to be shipped outShipping
 
  Shenzhen Hongswell Technology operates certified management systems compliant with:
 
 CertificatInformation
Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable

 

ISO 9001:2008

quality management systems

Certificat ISO 9001:2008
- SHENZHEN HONGSWELL TECHNOLOGY CO. , LTD.
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019

Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable

ISO 14001:2004

environmental management systems

Certificat ISO 14001:2004

- SHENZHEN HONGSWELL TECHNOLOGY CO. , LTD.

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 13 January 2019

Durable Outdoor XLPE Insulated Power Cable For Electricity Supply YJV Cable

OHSAS 18001:2007

assessment specification for occupational health & safety management systemsenvironmental management systems

Certificat OHSAS 18001:2007

- SHENZHEN HONGSWELL TECHNOLOGY CO. , LTD.

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 13 January 2019

  Customer services:

 

09.jpg

  RECOMMENDED ORDERING PARAMETERS

  CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Contact: Eric Tse +86 137 2348 6366
E-mail : hongswell@hotmail.com

Head office:No.123,Xiangshan avenue,The third industrial zone,Luotian community,Songgang Block,Baoan district,Shenzhen city,P.R.C.

 

  WARRANTY

 

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

Online Inquiry